Appearance | Sensing distance | Model | |
Operation mode | |||
NO | NC | ||
Unshielded |
5 mm | TL-W5MD1 2M *1 *3 | TL-W5MD2 2M *3 |
Appearance | Sensing distance | Output configuration | Model | |
Operation mode | ||||
NO | NC | |||
Unshielded |
1.5 mm | DC 3-wire, NPN | TL-W1R5MC1 2M *1 *2 *3 | --- |
3 mm | TL-W3MC1 2M *1 *2 *3 | TL-W3MC2 2M *1 *2 *3 | ||
5 mm | TL-W5MC1 2M *1 *2 *3 | TL-W5MC2 2M *2 | ||
20 mm | TL-W20ME1 2M *1 *2 *3 | TL-W20ME2 2M *1 | ||
Shielded |
5 mm | DC 3-wire, NPN | TL-W5E1 2M | TL-W5E2 2M |
DC 3-wire, PNP | TL-W5F1 2M | TL-W5F2 2M |
Model | TL-W5MD[] | |
Sensing distance | 5 mm ±10% | |
Set distance | 0 to 4 mm | |
Differential travel | 10% max. of sensing distance | |
Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on Data Sheet.) |
|
Standard sensing object | Iron, 18 × 18 × 1 mm | |
Response frequency *1 | 500 Hz | |
Power supply voltage (operating voltage range) |
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. | |
Leakage current | 0.8 mA max. | |
Control output |
Load current | 3 to 100 mA |
Residual voltage | 3.3 V max. (under load current of 100 mA with cable length of 2 m) | |
Indicators | D1 Models: Operation indicator (red), Setting indicator (green) D2 Models: Operation indicator (red) |
|
Operation mode (with sensing object approaching) |
D1 Models: NO D2 Models: NC Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details. |
|
Protection circuits | Load short-circuit protection, Surge suppressor | |
Ambient temperature range | Operating/Storage: -25 to 70°C (with no icing or condensation) | |
Ambient humidity range | Operating/Storage: 35% to 95% (with no condensation) | |
Temperature influence | ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | |
Voltage influence | ±2.5% max. of sensing distance at rated voltage in the rated voltage ±15% range | |
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | |
Dielectric strength | 1,000 VAC for 1 min between current-carrying parts and case | |
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | |
Shock resistance | Destruction: 500 m/s2 3 times each in X, Y, and Z directions | |
Degree of protection | IEC 60529 IP67, in-house standards: oil-resistant *2 | |
Connection method | Pre-wired Models (Standard cable length: 2 m) | |
Weight (packed state) | Approx. 80 g | |
Materials | Case | Heat-resistant ABS |
Sensing surface | ||
Accessories | Instruction manual |
Model | TL-W1R5MC1 | TL-W3MC[] | TL-W5MC[] | TL-W5E1 TL-W5E2 TL-W5F1 TL-W5F2 |
TL-W20ME1 TL-W20ME2 |
|
Sensing distance | 1.5 mm ±10% | 3 mm ±10% | 5 mm ±10% | 20 mm ±10% | ||
Set distance | 0 to 1.2 mm | 0 to 2.4 mm | 0 to 4 mm | 0 to 16 mm | ||
Differential travel | 10% max. of sensing distance | 1% to 15% of sensing distance |
||||
Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on Data Sheet.) |
|||||
Standard sensing object | Iron, 8 × 8 × 1 mm |
Iron, 12 × 12 × 1 mm |
Iron, 18 × 18 × 1 mm |
Iron, 50 × 50 × 1 mm |
||
Response frequency | 1 kHz min. | 600 Hz min. | 500 Hz min. | 300 Hz min. | 40 Hz min. | |
Power supply voltage (operating voltage range) |
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. | 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 20% max. |
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. |
|||
Current consumption | 15 mA max. at 24 VDC (no-load) | 10 mA max. | 15 mA max. at 24 VDC (no-load) |
8 mA at 12 VDC, 15 mA at 24 VDC |
||
Control output |
Load current |
NPN open collector 100 mA max. at 30 VDC max. |
NPN open collector 50 mA max. at 12 VDC (30 VDC max.) 100 mA max. at 24 VDC (30 VDC max.) |
200 mA | 100 mA max. at 12 VDC 200 mA max. at 24 VDC |
|
Residual voltage |
1 V max. (under load current of 100 mA with cable length of 2 m) |
1 V max. (under load current of 50 mA with cable length of 2 m) |
2 V max. (under load current of 200 mA with cable length of 2 m) |
1 V max. (under load current of 200 mA with cable length of 2 m) |
||
Indicators | Detection indicator (red) | |||||
Operation mode (with sensing object approaching) |
NO | C1 Models: NO C2/B2 Models: NC |
E1/F1 Models: NO E2/F2 Models: NC |
|||
Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details. | ||||||
Protection circuits | Reverse polarity protection, Surge suppressor | |||||
Ambient temperature range |
Operating/Storage: -25 to 70°C (with no icing or condensation) * | |||||
Ambient humidity range | Operating/Storage: 35% to 95% (with no condensation) | |||||
Temperature influence | ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | |||||
Voltage influence | ±2.5% max. of sensing distance at rated voltage in the rated voltage ±10% range |
±2.5% max. of sensing distance at rated voltage in the rated voltage ±20% range |
±2.5% max. of sensing distance at rated voltage in the rated voltage ±10% range |
|||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | |||||
Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case | |||||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | |||||
Shock resistance | Destruction: 500 m/s2 3 times each in X, Y, and Z directions | Destruction: 500 m/s2 10 times each in X, Y, and Z directions |
||||
Degree of protection | IEC 60529 IP67, in-house standards: oil-resistant * | |||||
Connection method | Pre-wired Models (Standard cable length: 2 m) | |||||
Weight (packed state) | Approx. 70 g | Approx. 80 g | Approx. 100 g | Approx. 210 g | ||
Materials | Case | Heat-resistant ABS | Aluminum die-cast | Heat-resistant ABS | ||
Sensing surface |
Heat-resistant ABS | |||||
Accessories | Mounting Bracket, Instruction manual |
Instruction manual |